Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(1): e13780, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36087039

RESUMO

PURPOSE: To estimate the clinical impact of differences between delivered and planned dose using dose metrics and normal tissue complication probability (NTCP) modeling. METHODS: Forty-six consecutive patients with prostate adenocarcinoma between 2010 and 2015 treated with intensity-modulated radiation therapy (IMRT) and who had undergone computed tomography on rails imaging were included. Delivered doses to bladder and rectum were estimated using a contour-based deformable image registration method. The bladder and rectum NTCP were calculated using dose-response parameters applied to planned and delivered dose distributions. Seven urinary and gastrointestinal symptoms were prospectively collected using the validated prostate cancer symptom indices patient reported outcome (PRO) at pre-treatment, weekly treatment, and post-treatment follow-up visits. Correlations between planned and delivered doses against PRO were evaluated in this study. RESULTS: Planned mean doses to bladder and rectum were 44.9 ± 13.6 Gy and 42.8 ± 7.3 Gy, while delivered doses were 46.1 ± 13.4 Gy and 41.3 ± 8.7 Gy, respectively. D10cc for rectum was 64.1 ± 7.6 Gy for planned and 60.1 ± 9.3 Gy for delivered doses. NTCP values of treatment plan were 22.3% ± 8.4% and 12.6% ± 5.9%, while those for delivered doses were 23.2% ± 8.4% and 9.9% ± 8.3% for bladder and rectum, respectively. Seven of 25 patients with follow-up data showed urinary complications (28%) and three had rectal complications (12%). Correlations of NTCP values of planned and delivered doses with PRO follow-up data were random for bladder and moderate for rectum (0.68 and 0.67, respectively). CONCLUSION: Sensitivity of bladder to clinical variations of dose accumulation indicates that an automated solution based on a DIR that considers inter-fractional organ deformation could recommend intervention. This is intended to achieve additional rectum sparing in cases that indicate higher than expected dose accumulation early during patient treatment in order to prevent acute severity of bowel symptoms.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Reto , Bexiga Urinária , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Dosagem Radioterapêutica
2.
JACC Case Rep ; 3(10): 1258-1263, 2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34471874

RESUMO

This paper describes the case of a patient who developed refractory heart failure due to a fistula from the left ventricle to the coronary sinus that was unintentionally created after a surgical myectomy and mitral valve replacement. Advanced image guidance with a pre-procedure 3-dimensional physical model and intraprocedure echocardiography fusion facilitated transcatheter plugging of the shunt with symptom resolution. (Level of Difficulty: Advanced.).

3.
Echocardiography ; 37(5): 769-780, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32338402

RESUMO

Increased catheter-based interventions in congenital and structural heart disease require imaging modalities to be oriented in the same visual perspective. The use of echocardiography-fluoroscopy fusion (EFF) imaging has been developed for better characterization of complex anatomy and to facilitate key steps in interventional procedures. This review will detail the technology behind EFF, the differences between the two ultrasound fusion systems, and essential features of EFF imaging in congenital and structural heart disease interventions.


Assuntos
Cardiopatias Congênitas , Radiografia Intervencionista , Cateterismo Cardíaco , Ecocardiografia , Fluoroscopia , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imagem Multimodal , Ultrassonografia de Intervenção
4.
J Appl Clin Med Phys ; 21(2): 14-25, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32058663

RESUMO

PURPOSE: To assess the performance and limitations of contour propagation with three commercial deformable image registration (DIR) algorithms using fractional scans of CT-on-rails (CTOR) and Cone Beam CT (CBCT) in image guided prostate therapy patients treated with IMRT/VMAT. METHODS: Twenty prostate cancer patients treated with IMRT/VMAT were selected for analysis. A total of 453 fractions across those patients were analyzed. Image data were imported into MIM (MIM Software, Inc., Cleveland, OH) and three DIR algorithms (DIR Profile, normalized intensity-based (NIB) and shadowed NIB DIR algorithms) were applied to deformably register each fraction with the planning CT. Manually drawn contours of bladder and rectum were utilized for comparison against the DIR propagated contours in each fraction. Four metrics were utilized in the evaluation of contour similarity, the Hausdorff Distance (HD), Mean Distance to Agreement (MDA), Dice Similarity Coefficient (DSC), and Jaccard indices. A subfactor analysis was performed per modality (CTOR vs. CBCT) and time (fraction). Point estimates and 95% confidence intervals were assessed via a Linear Mixed Effect model for the contour similarity metrics. RESULTS: No statistically significant differences were observed between the DIR Profile and NIB algorithms. However, statistically significant differences were observed between the shadowed NIB and NIB algorithms for some of the DIR evaluation metrics. The Hausdorff Distance calculation showed the NIB propagated contours vs. shadowed NIB propagated contours against the manual contours were 14.82 mm vs. 8.34 mm for bladder and 15.87 mm vs. 11 mm for rectum, respectively. Similarly, the Mean Distance to Agreement calculation comparing the NIB propagated contours vs. shadowed NIB propagated contours against the manual contours were 2.43 mm vs. 0.98 mm for bladder and 2.57 mm vs. 1.00 mm for rectum, respectively. The Dice Similarity Coefficients comparing the NIB propagated contours and shadowed NIB propagated contours against the manual contours were 0.844 against 0.936 for bladder and 0.772 against 0.907 for rectum, respectively. The Jaccard indices comparing the NIB propagated contours and shadowed NIB propagated contours against the manual contours were 0.749 against 0.884 for bladder and 0.637 against 0.831 for rectum, respectively. The shadowed NIB DIR, which showed the closest agreement with the manual contours performed significantly better than the DIR Profile in all the comparisons. The OAR with the greatest agreement varied substantially across patients and image guided radiation therapy (IGRT) modality. Intra-patient variability of contour metric evaluation was insignificant across all the DIR algorithms. Statistical significance at α = 0.05 was observed for manual vs. deformably propagated contours for bladder for all the metrics except Hausdorff Distance (P = 0.01 for MDA, P = 0.02 for DSC, P = 0.01 for Jaccard), whereas the corresponding values for rectum were: P = 0.03 for HD, P = 0.01 for MDA, P < 0.01 for DSC, P < 0.01 for Jaccard. The performance of the different metrics varied slightly across the fractions of each patient, which indicates that weekly contour propagation models provide a reasonable approximation of the daily contour propagation models. CONCLUSION: The high variance of Hausdorff Distance across all automated methods for bladder indicates widely variable agreement across fractions for all patients. Lower variance across all modalities, methods, and metrics were observed for rectum. The shadowed NIB propagated contours were substantially more similar to the manual contours than the DIR Profile or NIB contours for both the CTOR and CBCT imaging modalities. The relationship of each algorithm to similarity with manual contours is consistent across all observed metrics and organs. Screening of image guidance for substantial differences in bladder and rectal filling compared with the planning CT reference could aid in identifying fractions for which automated DIR would prove insufficient.


Assuntos
Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Análise Fatorial , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Masculino , Reconhecimento Automatizado de Padrão , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem , Reprodutibilidade dos Testes , Software , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
5.
Nanoscale ; 5(5): 2152-63, 2013 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-23389324

RESUMO

It has been recently reported that for some suspensions of magnetic nanoparticles the transverse proton relaxation rate, R(2), is dependent on the time that the sample is exposed to an applied magnetic field. This time dependence has been linked to the formation of linear aggregates or chains in an applied magnetic field via numerical modeling. It is widely known that chain formation occurs in more concentrated ferrofluids systems and that this has an affect on the ferrofluid properties. In this work we examine the relationships between colloidal stability, the formation of these linear structures, and changes observed in the proton transverse relaxation rate of aqueous suspensions of magnetic particles. A series of iron oxide nanoparticles with varying stabilizing ligand brush lengths were synthesized. These systems were characterized with dynamic light scattering, transmission electron microscopy, dark-field optical microscopy, and proton transverse relaxation rate measurements. The dark field optical microscopy and R(2) measurements were made in similar magnetic fields over the same time scale so as to correlate the reduction of the transverse relaxivity with the formation of linear aggregates. Our results indicate that varying the ligand length has a direct effect on the colloidal arrangement of the system in a magnetic field, producing differences in the rate and size of chain formation, and hence systematic changes in transverse relaxation rates over time. With increasing ligand brush length, attractive inter-particle interactions are reduced, which results in slower aggregate formation and shorter linear aggregate length. These results have implications for the stabilization, characterization and potentially the toxicity of magnetic nanoparticle systems used in biomedical applications.


Assuntos
Nanopartículas de Magnetita/química , Polietilenoglicóis/química , Di-Hidroxifenilalanina/química , Compostos Férricos/química , Luz , Magnetismo , Prótons , Espalhamento de Radiação , Suspensões , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...